A new methodology for the assessment of hand protection from ultraviolet exposure

Marina Khazova, Jacqueline O'Hagan, K. J.L. Grainger

    Research output: Contribution to journalArticlepeer-review

    1 Citation (Scopus)

    Abstract

    A number of industrial applications and public services involve occupational exposure to ultraviolet radiation (UVR) from a variety of lamps and lasers. The aim of this study was to develop a methodology for the assessment of the UV protection level for disposable gloves. Glove UV protection factor is defined as a time-scale increase in exposure permitted for the hand protected by a glove with respect to an unprotected hand. Our study showed that for all tested gloves a change in UVR attenuation with stretching is characteristic for the type of glove material and can be included as a scaling factor in the definition of UVR protection. Glove material has a bigger effect on UVR protection level than variations in the glove thickness or its colour. Examples of assessment of the 'worst case scenario' are compared with the protection level against a number of sources, together with the guidance on a simplified evaluation protocol. An application-specific assessment, illustrated for 'SmartWater' forensic examinations and biological trans-illuminators, demonstrates that some gloves provide inadequate protection against occupational UV exposure.

    Original languageEnglish
    Pages (from-to)265-274
    Number of pages10
    JournalRadiation Protection Dosimetry
    Volume121
    Issue number3
    DOIs
    Publication statusPublished - Dec 2006

    Fingerprint

    Dive into the research topics of 'A new methodology for the assessment of hand protection from ultraviolet exposure'. Together they form a unique fingerprint.

    Cite this